🎉 Up to 70% Off Selected ItemsShop Sale
HomeStore

Honeywell VR8300C4506 Gas Valve, 3/4 in Inlet, 3/4 in Outlet, Straight Flanged End, Natural Gas Gas, 0.5 psi Pressure

Product image 1

Honeywell VR8300C4506 Gas Valve, 3/4 in Inlet, 3/4 in Outlet, Straight Flanged End, Natural Gas Gas, 0.5 psi Pressure

Honeywell VR8300C4506 Gas Valve, 3/4 in Inlet, 3/4 in Outlet, Straight Flanged End, Natural Gas Gas, 0.5 psi Pressure

Honeywell Gas Valve, 3/4 in Inlet, 3/4 in Outlet, End Type: Straight Flanged, Gas Type: Natural Gas, Standing Pilot Ignition, 0.5 psi, 0 to 175 deg F, 24 VAC, 0.7 A, 60 Hz, Electrical Connection: 1/4 in Male Quick-Connect, 4-1/16 in W Overall, 6-1/8 in H Overall


  • Control includes safety shut-off, manual valve, two automaticOperators, pressure regulator and pilot adjustmentCompact sizeProvides two automatic valvesSolenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat endsDiaphragm operated second automatic valve opens under control of regulator, closes if gas or power supply is interruptedMeets codes requiring dual safety shut-offNatural to LP and LP to Natural conversion kits available for standard and slow opening gas valvesAll adjustments, wiring connections and pilot outlet are accessible from top of controlAdjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressureCompatible with ECO connectorLITE-RITE (off-pilot-on) lighting sequence
$101.65

Original: $338.82

-70%
Honeywell VR8300C4506 Gas Valve, 3/4 in Inlet, 3/4 in Outlet, Straight Flanged End, Natural Gas Gas, 0.5 psi Pressure

$338.82

$101.65

Product Information

Shipping & Returns

Description

Honeywell Gas Valve, 3/4 in Inlet, 3/4 in Outlet, End Type: Straight Flanged, Gas Type: Natural Gas, Standing Pilot Ignition, 0.5 psi, 0 to 175 deg F, 24 VAC, 0.7 A, 60 Hz, Electrical Connection: 1/4 in Male Quick-Connect, 4-1/16 in W Overall, 6-1/8 in H Overall


  • Control includes safety shut-off, manual valve, two automaticOperators, pressure regulator and pilot adjustmentCompact sizeProvides two automatic valvesSolenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat endsDiaphragm operated second automatic valve opens under control of regulator, closes if gas or power supply is interruptedMeets codes requiring dual safety shut-offNatural to LP and LP to Natural conversion kits available for standard and slow opening gas valvesAll adjustments, wiring connections and pilot outlet are accessible from top of controlAdjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressureCompatible with ECO connectorLITE-RITE (off-pilot-on) lighting sequence