Honeywell L8148E1265/U Aquastat Relay, SPST, Vertical Mounting, 180 to 240 deg F High Limit, 15 deg F Fixed Differential
Honeywell Aquastat Relay, 0.8 A at 24 VAC, 0.25 A at 0.25 to 12 VDC Maximum Low Voltage; 44.4 A at 120 VAC, 22.2 A at 240 VAC Locked Rotor, 120 VAC, 60 Hz, 255 psi Maximum Immersion Well Safe Operating, 4-1/2 in Capillary Length, Quick Connect/Screw, SPST, Vertical Mount, 180 to 240 deg F High Limit, 15 deg F Fixed Differential, 4-5/16 in L x 3-1/8 in W x 6-1/8 in H
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motorsHigh limit opens burner circuit onlyRequire 24 VAC thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E)Includes molex plug for use with vent damper, includes heat-conductive compound1-1/2 - 3 in D less well insulationElectrical burner rating: at full load: 0.8 A maximum at 24 VAC low voltage, 7.4 A at 120 VAC: 3.7 A at 240 VAC line voltage
- at locked rotor: 44.4 A at 120 VAC: 22.7 A at 240 VAC line voltage
- millivolt: 0.25 A at 1/4 - 12 VDCElectrical circulator rating: at full load: 7.4 A at 120 VAC, 3.7 A at 240 VAC
- at locked rotor: 44.4 A at 120 VAC, 22.2 A at 240 VAC0 - 95% RH non-condensing environmental conditions
Product Information
Product Information
Shipping & Returns
Shipping & Returns

Honeywell L8148E1265/U Aquastat Relay, SPST, Vertical Mounting, 180 to 240 deg F High Limit, 15 deg F Fixed Differential
Honeywell L8148E1265/U Aquastat Relay, SPST, Vertical Mounting, 180 to 240 deg F High Limit, 15 deg F Fixed Differential
Honeywell Aquastat Relay, 0.8 A at 24 VAC, 0.25 A at 0.25 to 12 VDC Maximum Low Voltage; 44.4 A at 120 VAC, 22.2 A at 240 VAC Locked Rotor, 120 VAC, 60 Hz, 255 psi Maximum Immersion Well Safe Operating, 4-1/2 in Capillary Length, Quick Connect/Screw, SPST, Vertical Mount, 180 to 240 deg F High Limit, 15 deg F Fixed Differential, 4-5/16 in L x 3-1/8 in W x 6-1/8 in H
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motorsHigh limit opens burner circuit onlyRequire 24 VAC thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E)Includes molex plug for use with vent damper, includes heat-conductive compound1-1/2 - 3 in D less well insulationElectrical burner rating: at full load: 0.8 A maximum at 24 VAC low voltage, 7.4 A at 120 VAC: 3.7 A at 240 VAC line voltage
- at locked rotor: 44.4 A at 120 VAC: 22.7 A at 240 VAC line voltage
- millivolt: 0.25 A at 1/4 - 12 VDCElectrical circulator rating: at full load: 7.4 A at 120 VAC, 3.7 A at 240 VAC
- at locked rotor: 44.4 A at 120 VAC, 22.2 A at 240 VAC0 - 95% RH non-condensing environmental conditions
Original: $420.88
-70%$420.88
$126.26Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Honeywell Aquastat Relay, 0.8 A at 24 VAC, 0.25 A at 0.25 to 12 VDC Maximum Low Voltage; 44.4 A at 120 VAC, 22.2 A at 240 VAC Locked Rotor, 120 VAC, 60 Hz, 255 psi Maximum Immersion Well Safe Operating, 4-1/2 in Capillary Length, Quick Connect/Screw, SPST, Vertical Mount, 180 to 240 deg F High Limit, 15 deg F Fixed Differential, 4-5/16 in L x 3-1/8 in W x 6-1/8 in H
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motorsHigh limit opens burner circuit onlyRequire 24 VAC thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E)Includes molex plug for use with vent damper, includes heat-conductive compound1-1/2 - 3 in D less well insulationElectrical burner rating: at full load: 0.8 A maximum at 24 VAC low voltage, 7.4 A at 120 VAC: 3.7 A at 240 VAC line voltage
- at locked rotor: 44.4 A at 120 VAC: 22.7 A at 240 VAC line voltage
- millivolt: 0.25 A at 1/4 - 12 VDCElectrical circulator rating: at full load: 7.4 A at 120 VAC, 3.7 A at 240 VAC
- at locked rotor: 44.4 A at 120 VAC, 22.2 A at 240 VAC0 - 95% RH non-condensing environmental conditions